Analysis and optimization of CHP plant Inowroclaw
Conducting energy audit at CHP plant in Soda Production facility Inowroclaw and recommendation of appropriate measures for achieving energy savings.
Services provided:
-
Energy audit at CHP plant in Soda Production facility Inowroclaw
-
Collecting relevant technical data
-
Conducting thermodynamic and techno-economic calculations of CHP plant
-
Identification of appropriate measures for achieving energy savings
-
Preparation and elaboration of a report with technical and ecomonic aspects of selected measures for achieving energy
savings
Key data:
- Four (4) coal fired steam boilers OP110 (110 t/h)
- Fresh steam pressure: 85 bar
- Fresh steam temperature: 465°C
- Two (2) back-pressure extraction steam turbines, rated power 17,5 MW
- Two (2) back-pressure extraction steam turbines, rated power 4,75 MW
- Eight (8) pressure reducing station
- Four (4) steam collectors
Time period: 2014