Waste Heat Recovery Plant Kronospan
Utilisation of waste heat from gas engine for the purpose of
safe and reliable supply of technological steam and heat for district heating
network.
Services provided:
- Establishment
of Ebsilon@Professional model
- Establishment
of Excel interface for plant performance calculations
- Heat
and mass balance calculations
- Plant performance calculations
Key data:
- MAN 20V35/44G
four-stroke medium-speed gas engine, rated power 10 MWe
- Exhaust
gas temperature: 395 °C
- Exhaust
gas mass flow: 59,5 t/h
- Technological
steam: 14 bar, 195 °C
- Heat
for district heating network, 5 bar, 103 °C
Time period: 2015